Test

CA45 Type (Temperature Range: -55°C to +125°C)

Conditions

Characteristics

Endurance

Apply the rated voltage at 85°C or the category voltage at 125°C for 2000 h, with circuit impedance ≤0.1Ω/V. After the test, stabilize at room temperature for 1–2 h before measurement.

Visual Inspection

No Visible Damage

DC Leakage Current

Not more than 1.25 times the initial limit value

Capacitance Change

Within ±10% of the initial value

Dissipation Factor

Not more than the initial limit value

Moisture Resistance

Store for 500 h at 65°C and 95% RH with no voltage applied. After the test, stabilize for 1–2 h under room temperature and humidity conditions before measurement.

Visual Inspection

No Visible Damage

DC Leakage Current

Not more than 1.5 times the initial limit value

Capacitance Change

Within ±10% of the initial value

Dissipation Factor

Not more than 1.2 times the initial limit value

Temperature

Stability

Step

Temperature °C

Duration (min)


+20℃

-55℃

+20℃

+85℃

+125℃

+20℃

1

+20

15

DC Leakage Current

IL

n/a

IL

10×IL

12.5×IL

IL

2

-55

15

Capacitance Change

n/a

-10/+0%

±5%

-0/+10%

-0/+20%

±5%

3

+20

15

Dissipation Factor

IL

1.5×IL

IL

1.5×IL

2×IL

IL

4

+85

15


IL — Initial limit value; n/a — Not applicable.

5

+125

15

6

+20

15

Surge

Voltage

1000 cycles at 125°C. Each cycle consists of charging for 30 s with the surge voltage applied, followed by discharging for 5 min 30 s (6 min total). The surge voltage is applied through a 1000Ω resistor. The surge voltage is 1.3 times the category voltage.

Visual Inspection

No Visible Damage

DC Leakage Current

Not more than the initial limit value

Capacitance Change

Within ±5% of the initial value

Dissipation Factor

Not more than the initial limit value

Mechanical

Shock

MIL-STD-202,

Method 213, Condition C

Visual Inspection

No Visible Damage

DC Leakage Current

Not more than the initial limit value

Capacitance Change

Within ±5% of the initial value

Dissipation Factor

Not more than the initial limit value

Equivalent Series Resistance (ESR)

Not more than the initial limit value

Vibration

MIL-STD-202,

Method 204, Condition D

Visual Inspection

No Visible Damage

DC Leakage Current

Not more than the initial limit value

Capacitance Change

Within ±5% of the initial value

Dissipation Factor

Not more than the initial limit value

Equivalent Series Resistance (ESR)

Not more than the initial limit value


© 2026 Song Tian  All Rights Reserved.   备案号:粤ICP备20041869号-2 腾云建站仅向商家提供技术服务